Welcome! In this article, we will take a closer look at the ACS-32 electronic scales, which can weigh up to 35 kg with an accuracy of 5 grams. These scales are equipped with a convenient LCD display with green backlight and a tare function. They are reliable in operation at temperatures from -10ยฐC to +40ยฐC, and their platform is made of stainless steel for durability and easy maintenance. To save energy, the scales automatically switch to sleep mode when not in use. A calibration mode is also available for professionals, accessible from the keyboard.

Electronic Scales ACS-32

Fixing ACS-32 Scale Issues (30 kg, 35 kg) Yourself

Even reliable equipment can occasionally malfunction. Don't worryโ€”some issues with your ACS-32 scales can be resolved on your own. Here are some common situations and how to fix them:

Power indicator is off

Check the following:

  1. Power cord is not connected.
  2. Poor plug contact with the outlet.
  3. Damaged power cord.
  4. Blown fuse.

Solution: a. Try replacing the power cord. b. Replace the fuse if necessary.

"Lb" appears on the screen with an alarm, then scales turn off

This error usually relates to power issues:

  1. Low battery charge.
  2. Prolonged use without recharging.

Solution: a. Charge the battery for 7 hours. b. Check if the power adapter is working properly.

Weight readings are unstable

This could be caused by:

  1. Low battery or moisture inside the unit.
  2. Loose connector between the weighing platform and the main unit.

Solution: a. Charge the battery for 7 hours. b. Check and, if needed, replace the connection cable.

"FULL" appears on screen with an alarm

This indicates a connection problem:

  1. Poor connection between the platform and the main unit.
  2. Broken cable between the platform and the main unit.

Solution: a. Inspect the cable for damage and ensure secure connections.

Scales show incorrect weight (too high or too low)

This may be due to:

  1. Loose connection between the platform and the main unit.
  2. Incorrect calibration.

Solution: a. Check the connection cable and reconnect properly. b. Calibrate the scales (see instructions below).

Calibration Instructions for ACS-32 Scales (35 kg)

If your scales display incorrect weight, follow this simple calibration guide:

  1. Turn on the scales. "0" should appear on the first display.
  2. Enter the calibration code: 97.55 (make sure to use the dot).
  3. Press the TARE button. "--------" will appear on the first display, indicating calibration mode.
  4. Press the 1 button. Numbers will appear on the middle display.
  5. By pressing 1, select the number 3015. This means a max weight of 30 kg and 15 kg calibration weight.
  6. Place a 15 kg standard weight on the platform.
  7. Press the Reset button.
  8. Press the TARE button again.
  9. Turn off the scales.
  10. Remove the weight from the platform.
  11. Turn the scales back on to verify calibration success.

Important: Be careful when entering the calibration code and follow the steps precisely.

We hope this information was helpful! If you have any questions, feel free to leave a comment.

Tags: electronic scales ACS-32 calibration scale repair manual

๐Ÿ› ๏ธ DIY Troubleshooting for Chinese Scales

Chinese scale malfunctions

Sometimes, our trusty measurement helpers โ€” Chinese electronic scales โ€” can run into minor issues. Donโ€™t worry! In most cases, you can fix them yourself at home. This article will guide you through the most common problems and how to solve them.

๐Ÿ’ก Problem: Power indicator does not light up

If you turn on the scale and the power indicator doesnโ€™t light up, check the following possible causes:

  1. ๐Ÿ”Œ The power cord is not connected to the scale or outlet.
  2. ๐Ÿ”Œ Loose plug connection. Try unplugging and plugging it back in.
  3. โš ๏ธ The power cord is damaged or broken. Carefully inspect for visible defects.
  4. โš ๏ธ The fuse has blown (if your model has one).

๐Ÿ› ๏ธ Solution:

  • โœ… Replace the power cord if damaged.
  • โœ… Replace the fuse with an identical one if youโ€™re sure itโ€™s the issue.

๐Ÿ“‰ Problem: Display shows "Lb" and scale shuts down

If the display shows "Lb" with a warning signal and the scale shuts off, this usually points to power issues:

  1. ๐Ÿ”‹ Low battery charge.
  2. ๐Ÿ”‹ Prolonged use without charging may have caused deep discharge.

๐Ÿ› ๏ธ Solution:

  • โœ… Plug the scale into a power source and charge it for the recommended time (usually around 7 hours).
  • โœ… Check the power adapterโ€™s condition by testing with another outlet or using a known-working adapter.

โš–๏ธ Problem: Weight readings are unstable

If weight readings keep changing and wonโ€™t stabilize, check the following:

  1. ๐Ÿ”‹ Low battery charge (especially on battery-powered models).
  2. ๐Ÿ’ง Moisture has entered the scaleโ€™s body.
  3. ๐Ÿ”Œ Loose connection between the main unit and the weighing platform.

๐Ÿ› ๏ธ Solution:

  • โœ… Charge the battery as recommended.
  • โœ… If moisture is suspected, turn off the scale and let it dry thoroughly in a warm, dry place.
  • โœ… Check and reconnect the plug between the unit and platform if needed.

๐Ÿ›‘ Problem: Display shows "FULL" and alarm sounds

The "FULL" message usually doesnโ€™t indicate overload, but rather a connection issue between the scaleโ€™s parts:

  1. ๐Ÿ”Œ Loose connection between the main unit and weighing platform.
  2. โš ๏ธ Damaged cable between the main unit and platform.

๐Ÿ› ๏ธ Solution:

  • โœ… Check and secure the connection plug.
  • โœ… Carefully inspect the cable for visible damage. Repair or replace it if needed.

๐ŸŒก๏ธ Problem: Incorrect weight readings (too high or low)

Incorrect weight readings may be caused by:

  1. ๐Ÿ”Œ Loose connection between main unit and platform.
  2. โš™๏ธ Scale calibration is off.

๐Ÿ› ๏ธ Solution:

  • โœ… Check and secure the connection plug.
  • โœ… Calibrate the scale according to your modelโ€™s manual. General calibration steps:
    1. Turn on the scale.
    2. Find and press the "CAL" or "MODE" button and hold it for a few seconds.
    3. "CAL" or a calibration weight value may appear on the display.
    4. Place the correct calibration weight on the platform.
    5. Wait for the calibration to complete (the display may show "PASS" or another confirmation).
    6. Remove the weight and turn off the scale.

We hope these tips help you get your Chinese scales back up and running! If you encounter more serious issues, we recommend contacting a professional.

Tags: Chinese scales electronic scales scale issues scale repair DIY repair calibration scale diagnostics Lb error FULL error

๐Ÿ› ๏ธ Troubleshooting and Calibrating OXI, ACS, TCS Scales (30โ€“600 kg) at Home

OXI, ACS, TCS Scales

โš ๏ธ Common Issues with OXI, ACS, TCS Scales and How to Fix Them

Letโ€™s go over some typical problems that may occur with your OXI, ACS, or TCS scales (30kg to 600kg capacity) and how you can troubleshoot them yourself.

๐Ÿ”Œ Power Indicator Doesn't Light Up

  1. Check if the power cord is securely connected to the scale and power outlet.
  2. Make sure the plug and socket are not damaged.
  3. Inspect the power cord for breaks or bends.
  4. Check the fuse (if your model has one).

Solution: a. Try using a known working power cord. b. Replace the fuse with one of the same specifications.

๐Ÿ”‹ Display Shows "Lb" and Shuts Down

  1. The battery might be low and needs recharging.
  2. Prolonged use without charging may have deeply discharged the battery.

Solution: a. Plug the scale into the power outlet and charge it for the recommended time (usually 7 hours). b. Check the power supply for proper voltage output.

โš–๏ธ Unstable Weight Readings

  1. Check battery level โ€” low voltage can cause instability. Also, ensure the scale is not in a humid environment.
  2. Inspect the connector between the head unit and platform for loose contact or dirt.

Solution: a. Charge the battery for 7 hours. b. Disconnect and reconnect the connector, ensuring a firm fit. Clean the contacts if needed.

๐Ÿ›‘ "FULL" Message and Alarm Sound

  1. Check the connection between the head unit and the weighing platform.
  2. The cable may be damaged or disconnected.

Solution: a. Carefully inspect the cable for damage and ensure tight connector contact.

๐Ÿ“‰ Weight Reading Too High or Too Low

  1. Check the connection between the head unit and the platform.
  2. Calibration may have been lost.

Solution: a. Check connection integrity. b. Perform scale calibration (see instructions below).

โš™๏ธ Calibration of OXI, Planeta Vesov, Tandem Scales (Code Selection)

OXI, Planeta Vesov, and Tandem scales come in various versions, but they often use similar processors. Calibration codes may differ, so you need to try the right one from the list below. The rest of the calibration procedure is usually the same.

๐Ÿ”‘ Calibration Codes (Possible Options):

3658, 2068, 2069, 7247, 8818, 8518, 5867, 1068, 7561, 9848, 2038, 1589 (for lower models)
and with a dot (for higher models): 36.58, 20.68, 20.69, 72.47, 88.18, 85.18, 58.67, 10.68, 75.61, 98.48, 20.38, 15.89

๐Ÿ“ Calibration Instructions:

  1. Turn on the scale. The main display should show "0.000".
  2. Enter a calibration code (try codes from the list in order).
  3. Press the TARE button. A half-zero "0" may appear in the top-right corner of the second display (indicating entry into calibration mode).
  4. Press the 1 button.
  5. Press the TARE button again. The third display may show "----".
  6. Place an accurate calibration weight (50โ€“100 kg) on the platform.
  7. Enter the exact calibration weight value (e.g., 50.00 if using a 50kg weight).
  8. Press the TARE button.
  9. Enter the maximum capacity of your scale (e.g., 100.00 or 300.00). In some models, the decimal point may be omitted.
  10. Press the TARE button.
  11. Enter the graduation value (usually 05).
  12. Press the TARE button.
  13. Turn off the scale.
  14. Remove the calibration weight.
  15. Turn the scale back on and verify calibration accuracy.

Note: Be careful when entering zeros and decimal points. Incorrect input may lead to inaccurate calibration.

We hope this information helps you maintain and calibrate your scales! Feel free to leave comments if you have any questions.